ZF-LH Flow Display Controller
The ZF-LH flow display controller measures flow using a movable magnetic throttling orifice plate sensor, detecting the pressure differential as fluid passes through. The orifice plate moves to display the flow rate, with an optional magnetic switch for control. It is suitable for non-corrosive liquids and fluids with minimal solid or ferromagnetic impurities, ideal for lubricating systems. The device supports a working pressure of 1.6MPa and fluid viscosities from 30 to 600 mm²/s.
Flow Controllers
Contact Us

Overview:

Measurement Type: Pressure differential-based flow measurement using a magnetic throttling orifice plate

Output Options: Optional magnetic switch for control

Applications: Suitable for non-corrosive liquids, lubrication oil monitoring in systems, and fluids with low solid or ferromagnetic impurities

Pipe Diameter Range: DN10 to DN25, thread connection

Working Pressure: Up to 1.6MPa


Key Technical Specifications:

Display Accuracy: ±5%

Control Accuracy: ±5%

Environmental Temperature: -40°C to +40°C

Medium Temperature: -40°C to +70°C

Relative Humidity: ≤85%Rh

Liquid System Materials: 1Cr18Ni9Ti, Quartz Glass

Output Contact Rating: 220VAC max / 40W max