Products
Overview:
● Measurement Type: Float-based variable area flow measurement
● Output Options: Local display, remote transmission, control alarm
● Explosion-Proof Versions: Standard, intrinsically safe, and explosion-proof models
● Applications: Industrial process control for small flow and low-velocity fluids in complex environments
Key Technical Specifications:
● Measuring Range:
o Water (20°C): 6–15,000 L/h
o Air (0.1013MPa, 20°C): 0.05–4,000 m³/h
● Turndown Ratio: 10:1 (special type up to 20:1)
● Accuracy: Standard 1.6%, special type 1.0%
● Operating Pressure:
o DN15-DN50: PN4.0MPa (special type 25MPa)
o DN80-DN100: PN1.6MPa (special type 16MPa)
o Jacketed version: 1.6MPa
● Medium Temperature:
o Standard: -80°C to +220°C
o High-temperature: Up to 300°C
o PTFE-lined: ≤85°C
● Environmental Temperature: -40°C to +120°C (remote type ≤65°C)
● Medium Viscosity:
o DN15: ≤5mPa.s (H15.1-H15.3), ≤30mPa.s (H15.4-H15.9)
o DN25: ≤250mPa.s
o DN50-DN150: ≤300mPa.s
● Display:
o Instantaneous flow: 0-50,000
o Totalized flow: 0-99,999,999
● Output Signals:
o Standard: 4-20mA (two-wire)
o Pulse: Minimum interval 50ms
o Alarm: Open collector, max 100mA@30VDC, internal resistance 100Ω
● Power Supply:
o Standard: 24VDC (12-36VDC)
o AC Version: 220VAC (86-265VAC)
o Battery Version: 3.6V 4AH NiMH battery
● Connection:
o Standard: Flange
o Special: Custom flange
o Threaded: Standard or custom threads
● Electrical Interface: M20×1.5, PG11, 1/2”NPT
● Standard Height: 250mm (except specific installation types)
● Protection Rating: IP65
● Explosion-Proof Rating:
o Intrinsically Safe: Exia Ⅱ CT5Ga
o Flameproof: Exd Ⅱ CT5Gb
Downloads
Related Products
Contact Us
If you're interested or have any questions please don't hesitate to reach out. Send us a message anytime, and we'll respond promptly!